Air Consumption w/ Positioner-Dynamic
- 5 scfm (0.142 m³/min) (Max.) at 100 psi (690 kPa) Supply
Air Consumption w/ Positioner-Static
- 0.30 scfm (0.008 m³/min) at 40 psi (275 kPa) Supply
Effective Area
- see Data Sheet for Details
Piston Diameter
- see Data Sheet for Details
Positioner
- Suitable for All Standard Instrument Air Signals, Direct or Reverse Acting, Top or Bottom Loading
Standard Accessories
- Integrally Piped Cushion-loading Regulator & Gauge (For Units with Positioners Only)
Stroke Length
- 1/4" to 10". Longer Strokes are available, Consult the Factory.
Supply Pressure
- 20 to 100 psi (138 to 690 kPa)
Thrust
- Thrust, T, Equals the Product of Piston Effective Area, A, Multiplied by Supply Pressure Differential, ∆P, [up to 100 psi (690 kPa)]. T=(A)∆P. Example: Develop the Thrust of a GB51 Actuator with a 100 psi (690 kPa) Supply & A 20 psi (138 kPa) Cushion Load